Alarms

Unified inbox — grid operations and electrical-safety alarms

40
Total Alarms
21
Active
7
Critical (open)
8
Resolved
SeverityAlarmSourceLocationTimeStatusActions
Critical
Suspected e-trike charging — 1h38m sustained 18A
Current draw 18A persisted for 98 minutes on residential circuit (rated 30A). Pattern matches e-trike slow-charge signature. 7 similar events at this address in last 60 days.
SAF-2026-0520-001 · Abnormal Charging
Safety WatchBrgy. Pasong Tamo · Quezon City2m agoActive
View
Critical
Grid frequency deviation 59.82 Hz
System frequency dropped to 59.82 Hz — BESS fast frequency response activated automatically across the Luzon portfolio.
GRID-0001 · Grid Stability
Grid OperationsLuzon Grid · SUB-0054m agoActive
View
Critical
Unit trip — Pagbilao Thermal Unit 2
Pagbilao coal-fired Unit 2 tripped on high condenser back-pressure. 382 MW lost; reserve dispatch in progress.
GRID-0002 · Generation
Grid OperationsPagbilao Power Station · Quezon11m agoActive
View
Warning
Reservoir level low — Ambuklao Hydro
Ambuklao reservoir at 752.1 MASL, 1.4 m above minimum operating level. Generation derated to preserve head.
GRID-0003 · Generation
Grid OperationsAmbuklao Hydro · Benguet19m agoActive
View
Warning
BESS state-of-charge below 15%
Marikina Riverbanks battery at 12% SoC — discharge suspended until recharge window.
GRID-0004 · DER Fleet
Grid OperationsDER-BS-007 · Marikina27m agoActive
View
Warning
Voltage deviation on Feeder FDR-004A
Feeder FDR-004A reading 245.2 V against a 240 V threshold — volt-var response engaged on local inverters.
GRID-0005 · Power Quality
Grid OperationsMakati · SUB-00438m agoActive
View
Critical
Earth leakage 64mA — local breaker tripped
Sustained earth leakage current 64mA detected. Tier-1 local breaker tripped within 38ms. Premise off-grid pending field check.
SAF-2026-0520-002 · Earth Leakage
Safety WatchBrgy. Bahay Toro · Quezon City42m agoAcknowledged
Critical
Communication loss — Greenhills Solar
No telemetry from Greenhills Shopping Center Solar for over 5 minutes. SCADA poll timing out.
GRID-0006 · Communications
Grid OperationsDER-PV-009 · San Juan52m agoActive
View
Warning
Hosting capacity above 80% — Makati
Aggregate DER export at Makati substation reached 83% of approved hosting capacity. New connections require study.
GRID-0007 · Hosting Capacity
Grid OperationsMakati · SUB-0041h agoAcknowledged
Warning
Wind farm curtailment — Caparispisan
Caparispisan wind farm curtailed 18 MW on transmission constraint instruction from the system operator.
GRID-0008 · Generation
Grid OperationsCaparispisan Wind · Ilocos Norte1h agoAcknowledged
Warning
Recurring undervoltage at peak hours
sensor SS-PASONG-TAMO-011 consistently sees voltage < 198V between 19:00-21:00. Recommend feeder review.
SAF-2026-0520-101 · Undervoltage
Safety WatchBrgy. Pasong Tamo · Quezon City2h agoAcknowledged
Warning
Cooking line connector 78°C
Cooking circuit connector heating up at sensor SS-BAHAY-TORO-005; suggests loose terminal.
SAF-2026-0520-108 · Overtemperature
Safety WatchBrgy. Bahay Toro · Quezon City2h agoAcknowledged
Warning
Sustained overcurrent — rate-limited
Current draw 22A on 20A-rated lighting circuit at sensor SS-PROJECT-8-009. Tier-1 rate-limit engaged.
SAF-2026-0520-113 · Overcurrent
Safety WatchBrgy. Project 8 · Quezon City2h agoAcknowledged
Warning
Recurring undervoltage at peak hours
sensor SS-PANSOL-012 consistently sees voltage < 198V between 19:00-21:00. Recommend feeder review.
SAF-2026-0520-117 · Undervoltage
Safety WatchBrgy. Pansol · Quezon City2h agoAcknowledged
Warning
Inverter temperature warning
Pasig Warehouse District Solar inverter at 78 °C — derating threshold approaching.
GRID-0009 · DER Fleet
Grid OperationsDER-PV-014 · Pasig2h agoAcknowledged
Critical
Refrigerator circuit 88°C — sustained 6 min
Sari-sari store refrigerator circuit temperature reached 88°C, threshold 70°C. Tier-1 rate-limit engaged. Field unit dispatched.
SAF-2026-0520-003 · Overtemperature
Safety WatchBrgy. Pasong Tamo · Quezon City2h agoAcknowledged
Warning
OCPP heartbeat timeout — EV charger
QC Vertis North EV charger missed three consecutive OCPP heartbeats. Charger marked degraded.
GRID-0010 · Interoperability
Grid OperationsDER-EV-013 · Quezon City3h agoAcknowledged
Warning
Likely e-trike slow charge — 40 min
Pattern matches e-trike slow charging at sensor SS-PASONG-TAMO-019. Below trip threshold.
SAF-2026-0520-102 · Abnormal Charging
Safety WatchBrgy. Pasong Tamo · Quezon City3h agoActive
View
Warning
Overvoltage 244V — 12 min
Brief overvoltage at sensor SS-BAHAY-TORO-012, likely solar export peak. Within tolerance but logged.
SAF-2026-0520-109 · Overvoltage
Safety WatchBrgy. Bahay Toro · Quezon City3h agoActive
View
Warning
Connector temperature 72°C
Contactor temperature elevated at sensor SS-PROJECT-8-021. Recommend tightening or replacement.
SAF-2026-0520-114 · Overtemperature
Safety WatchBrgy. Project 8 · Quezon City3h agoActive
View
Warning
Likely e-trike slow charge — 40 min
Pattern matches e-trike slow charging at sensor SS-PANSOL-020. Below trip threshold.
SAF-2026-0520-118 · Abnormal Charging
Safety WatchBrgy. Pansol · Quezon City3h agoActive
View
Critical
Arc fault detected — premise isolated
AFCI flagged signature event. Premise auto-isolated within 42ms. Field crew confirmed degraded insulation in fuse holder; replaced.
SAF-2026-0520-004 · Arc Fault
Safety WatchBrgy. Project 8 · Quezon City3h agoResolved
Warning
Reverse power flow — Muntinlupa Feeder 2
Reverse power flow detected on Muntinlupa Feeder 2; dynamic operating envelope adjustment triggered.
GRID-0011 · Power Quality
Grid OperationsMuntinlupa · SUB-0063h agoResolved
Critical
E-trike charging on neighbour's line (theft signature)
Off-hour 14A draw on lighting circuit (rated 20A). Repeat pattern across 3 nights; voltage drop on neighbour's monitored circuit suggests illegal tap.
SAF-2026-0520-005 · Abnormal Charging
Safety WatchBrgy. Pasong Tamo · Quezon City4h agoAcknowledged
Warning
Sustained overcurrent — rate-limited
Current draw 22A on 20A-rated lighting circuit at sensor SS-PASONG-TAMO-024. Tier-1 rate-limit engaged.
SAF-2026-0520-103 · Overcurrent
Safety WatchBrgy. Pasong Tamo · Quezon City4h agoActive
View
Showing 1–25 of 40 alarms