San Lorenzo Wind Farm
San Lorenzo, Guimaras · 54 MW · commissioned 2014 · AboitizPower — Wind
RUNNING
Grid Interface
Reactive power
3.3 MVAr
capacitive (voltage support)
Power factor
0.960
meets grid code
Available capacity
10.6 MW
at limit
Dispatch state
Free run
output near capability
Asset Overview
Location
Guimaras
San Lorenzo, Guimaras
Nameplate
54 MW
Current output
12 MW
22% of rated
Capacity factor
37%
Hub wind speed
8.3 m/s
gust 11.6 m/s
Turbines
27/27
generating
Availability
96.5%
Rotor / hub
90 m
80 m hub height
Power Curve
Theoretical curve vs. 27 live turbine operating points · cut-in 3 · rated 12 · cut-out 25 m/s
Wind Rose
Direction frequency · prevailing 187° · 8.3 m/s mean
Generation Trend
San Lorenzo Wind Farm · 23 MW avg
Turbine Fleet
27 wind turbine generators
| Turbine | Status | Rated | Output | Rotor RPM | Pitch | Yaw | Gearbox °C | Vib mm/s |
|---|---|---|---|---|---|---|---|---|
| WTG-01 | Generating | 2000 kW | 663 kW | 10.7 | 0.8° | 197° | 60.2° | 2.4 |
| WTG-02 | Generating | 2000 kW | 322 kW | 9.3 | 1.1° | 189° | 59° | 1.7 |
| WTG-03 | Generating | 2000 kW | 468 kW | 9.9 | 1.8° | 195° | 57.8° | 1.9 |
| WTG-04 | Generating | 2000 kW | 593 kW | 10.4 | 1.6° | 194° | 60.5° | 1.9 |
| WTG-05 | Generating | 2000 kW | 233 kW | 8.9 | 0.5° | 172° | 57.1° | 1.6 |
| WTG-06 | Generating | 2000 kW | 207 kW | 8.8 | 2.2° | 167° | 55.5° | 1.8 |
| WTG-07 | Generating | 2000 kW | 682 kW | 10.7 | 2.3° | 166° | 61.9° | 2.1 |
| WTG-08 | Generating | 2000 kW | 339 kW | 9.4 | 2.6° | 171° | 56.7° | 2 |
| WTG-09 | Generating | 2000 kW | 204 kW | 8.8 | 0.6° | 184° | 54.9° | 1.5 |
| WTG-10 | Generating | 2000 kW | 382 kW | 9.5 | 0.8° | 161° | 58.5° | 1.6 |
| WTG-11 | Generating | 2000 kW | 639 kW | 10.6 | 0.3° | 176° | 61.5° | 1.9 |
| WTG-12 | Generating | 2000 kW | 265 kW | 9.1 | 2.8° | 183° | 58.6° | 2 |
| WTG-13 | Generating | 2000 kW | 718 kW | 10.9 | 0.6° | 186° | 61.3° | 2.4 |
| WTG-14 | Generating | 2000 kW | 419 kW | 9.7 | 1.7° | 176° | 57.5° | 2 |
| WTG-15 | Generating | 2000 kW | 679 kW | 10.7 | 1.2° | 181° | 61.2° | 2.3 |
| WTG-16 | Generating | 2000 kW | 359 kW | 9.4 | 3° | 187° | 58.8° | 1.6 |
| WTG-17 | Generating | 2000 kW | 279 kW | 9.1 | 0.3° | 171° | 56.6° | 1.6 |
| WTG-18 | Generating | 2000 kW | 315 kW | 9.3 | 0.8° | 199° | 58.7° | 1.5 |
| WTG-19 | Generating | 2000 kW | 273 kW | 9.1 | 1.8° | 197° | 56.6° | 1.6 |
| WTG-20 | Generating | 2000 kW | 588 kW | 10.4 | 0.2° | 174° | 59.3° | 2 |
| WTG-21 | Generating | 2000 kW | 525 kW | 10.1 | 0° | 188° | 58.6° | 2.2 |
| WTG-22 | Generating | 2000 kW | 521 kW | 10.1 | 2.6° | 177° | 58.3° | 2.2 |
| WTG-23 | Generating | 2000 kW | 198 kW | 8.8 | 0.1° | 167° | 55.9° | 1.9 |
| WTG-24 | Generating | 2000 kW | 603 kW | 10.4 | 0.9° | 197° | 60.8° | 2 |
| WTG-25 | Generating | 2000 kW | 320 kW | 9.3 | 1.7° | 168° | 58.3° | 1.9 |
| WTG-26 | Generating | 2000 kW | 698 kW | 10.8 | 2° | 179° | 60.7° | 2.3 |
| WTG-27 | Generating | 2000 kW | 538 kW | 10.2 | 0.7° | 193° | 60.6° | 2.2 |